Cookie-urile ne ajută să oferim serviciile noastre. Utilizând aceste servicii, acceptați modul în care utilizăm cookie-urile. Aflați mai multe.
Filteaza
-10%
Cereti Detalii

APC ACRD601

APC ACRD601, 600 milimetri, 1070 milimetri, 1991 milimetri, 391 kilograme, 850 milimetri, 1137 milimetri

  • Pret lista VRS: 87.81271  LEI
  • Discount: 8.78127  LEI (-10%)

79.03144 LEI cu TVA
66.41297  LEI 13.09275 14.12832 $
fără TVA
STOC ACTUAL: La comanda -

Transport gratuit !

  • Livrare in 30 de zile.

Comandati telefonic si prin email:

  • Telefon: 073 555 0001
  • Email: contact@verasys.com


In functie de volumul cererii, va putem oferi un alt discount fata de pretul de lista al produsului .

* Comanda minima initiala este de 1000 de EURO fara TVA.
* Verasys se adreseaza exclusiv persoanelor juridice cu capital privat sau de stat.
* Toate produsele prezentate pe site au garanția oferita de producător sau furnizor.
* Informatiile pot contine mici inadvertente, unele specificaţii sau preţul, pot fi modificate de catre producător fără preaviz sau pot conţine erori de operare.
* Poza produsului are caracter informativ.

Descriere furnizor

InRow RD, 600mm Air Cooled, 460-480V, 60Hz


Descriere APC ACRD601

APC ACRD601. Lărgime: 600 milimetri, Adâncime: 1070 milimetri, Înălţime: 1991 milimetri. Lăţime de ambalaj: 850 milimetri, Adâncimea de ambalaj: 1137 milimetri, Înălţime de ambalaj: 2166 milimetri

Active Airflow ControlMonitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.Air filtrationRemoves dirt and other particulates from the intake air for cleaner supply air.Architecturally neutralUnobtrusive design and coloring, blends in with the surroundings.Capacity ControlCooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.CastersProvides flexibility to move the unit to wherever cooling is required.Containment system compatibleThe unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiencyContinuous current monitoringPermits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).Direct drive motorsStress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.Ease of UseSimplifies future planning by allowing side to side equipment to be placed anywhere in the data center.Easy to installInnovative design allows for fast, easy installation by almost anybody.EfficiencyIncreases the capacity of the air conditioner by supplying a warmer return air temperature.Electronic expansion valveRefrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoringElectronically Commutated FansProvide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.Enclosure system compatibleSpecifically designed to work with Netshelter Enclosures.Fan guardsA safety measure that provides protection from the fan opening by covering the inlet.Fault-tolerant fan systemIn the event of a fan failure, the remaining fan(s) will continue to operate.Field replaceable componentsFans and electronics module can be readily replaced without uninstalling the unit.FlexibilitySupport for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containmentFront service accessThe system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.Green RefrigerantEnvironmentally friendly refrigerant that can offer LEED points.Hardwire capableFor installations where hard wiring is required or prefered.Head pressure controlModulates refrigerant head pressure to protect from coil freeze.High Sensible-to-Total Cooling RatioAchieved by careful sizing of heat exchanger coils.Horizontal airflow patternRemoves heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.Increased capacityHigher rate of heat removal allows more equipment to be installed in each rack.Local area networkCreates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situationsMinimizes Air MixingDelivers cool, conditioned air directly to the inlet of IT equipment.Modular strategyModular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Operational efficiencyWarmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Predictive failure notificationMaximizes system availability by providing early warning of required fan or filter replacement.Programmable input/output contactsAllows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.Rack Inlet Temperature ControlReduces the risk of hot spots at the rack levelReal-Time Capacity MonitoringReal-time display of current and available cooling.Rear containmentEnsures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.Scalable DesignModular design provides scalable solutions to add cooling as demand increases.Small FootprintEfficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.Temperature DisplayMonitors and displays temperature to prevent overheating.Touch-screen GUIEnables easy configuration, full monitoring, and event logging



Specificații tehnice APC ACRD601

Lărgime 600 milimetri
Adâncime 1070 milimetri
Înălţime 1991 milimetri
Greutate 391 kilograme
Lăţime de ambalaj 850 milimetri
Adâncimea de ambalaj 1137 milimetri
Înălţime de ambalaj 2166 milimetri
Greutatea pachetului 436 kilograme
Culoarea produsului Negru
Temperatura maximă de funcţionare 50 °C

* Specificațiile tehnice si descrierile pot fi modificate fără preaviz de către producător.

Produse din aceeași categorie