- Cod produs: ACRD601P
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Aparut din: 18.01.2017
- Garanție: Maxim 5 ani
APC ACRD601P
* Comanda minima initiala este de 1000 de EURO fara TVA.
* Verasys se adreseaza exclusiv persoanelor juridice cu capital privat sau de stat.
* Toate produsele prezentate pe site au garanția oferita de producător sau furnizor.
* Informatiile pot contine mici inadvertente, unele specificaţii sau preţul, pot fi modificate de catre producător fără preaviz sau pot conţine erori de operare.
* Poza produsului are caracter informativ.
Descriere APC ACRD601P
APC ACRD601P. Lărgime: 600 milimetri, Adâncime: 1070 milimetri, Înălţime: 1991 milimetri. Lăţime de ambalaj: 850 milimetri, Adâncimea de ambalaj: 1137 milimetri, Înălţime de ambalaj: 2166 milimetri
Active Airflow ControlMonitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.Air filtrationRemoves dirt and other particulates from the intake air for cleaner supply air.Architecturally neutralUnobtrusive design and coloring, blends in with the surroundings.Capacity ControlCooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.CastersProvides flexibility to move the unit to wherever cooling is required.Containment system compatibleThe unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiencyContinuous current monitoringPermits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).Direct drive motorsStress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.Ease of UseSimplifies future planning by allowing side to side equipment to be placed anywhere in the data center.Easy to installInnovative design allows for fast, easy installation by almost anybody.EfficiencyIncreases the capacity of the air conditioner by supplying a warmer return air temperature.Electronic expansion valveRefrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoringElectronically Commutated FansProvide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.Enclosure system compatibleSpecifically designed to work with Netshelter Enclosures.Fan guardsA safety measure that provides protection from the fan opening by covering the inlet.Fault-tolerant fan systemIn the event of a fan failure, the remaining fan(s) will continue to operate.Field replaceable componentsFans and electronics module can be readily replaced without uninstalling the unit.FlexibilitySupport for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containmentFront service accessThe system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.Green RefrigerantEnvironmentally friendly refrigerant that can offer LEED points.Hardwire capableFor installations where hard wiring is required or prefered.Head pressure controlModulates refrigerant head pressure to protect from coil freeze.High Sensible-to-Total Cooling RatioAchieved by careful sizing of heat exchanger coils.Horizontal airflow patternRemoves heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.Increased capacityHigher rate of heat removal allows more equipment to be installed in each rack.Local area networkCreates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situationsMinimizes Air MixingDelivers cool, conditioned air directly to the inlet of IT equipment.Modular strategyModular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Operational efficiencyWarmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Predictive failure notificationMaximizes system availability by providing early warning of required fan or filter replacement.Programmable input/output contactsAllows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.Rack Inlet Temperature ControlReduces the risk of hot spots at the rack levelReal-Time Capacity MonitoringReal-time display of current and available cooling.Rear containmentEnsures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.Scalable DesignModular design provides scalable solutions to add cooling as demand increases.Small FootprintEfficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.Temperature DisplayMonitors and displays temperature to prevent overheating.Touch-screen GUIEnables easy configuration, full monitoring, and event logging
Specificații tehnice APC ACRD601P
Lărgime | 600 milimetri |
Adâncime | 1070 milimetri |
Înălţime | 1991 milimetri |
Greutate | 402 kilograme |
Lăţime de ambalaj | 850 milimetri |
Adâncimea de ambalaj | 1137 milimetri |
Înălţime de ambalaj | 2166 milimetri |
Greutatea pachetului | 447 kilograme |
Culoarea produsului | Negru |
Temperatura maximă de funcţionare | 50 °C |
* Specificațiile tehnice si descrierile pot fi modificate fără preaviz de către producător.
Produse din aceeași categorie
-
-10%
APC ACRD100
APC InRow RD, 300mm, Statatoare, Negru, R410A, cUL Listed,C-tick,CE,UL Listed, 208/230 V, 300 x 1070 x 1991 milimetri- Cod: ACRD100
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
68.93832 LEI cu TVA57.93136 LEI 11.421 11.655$ fără TVADiscount: -7.65981 LEI -
-10%
APC ACRD200
APC InRow RD, 300mm, Fluid Cooled, 208-230V, 60Hz, Statatoare, Negru, Water, Glycol, R410A, cUL Listed,C-tick,CE,UL Listed, 208/230 V- Cod: ACRD200
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
66.68987 LEI cu TVA56.04191 LEI 11.048 11.274$ fără TVADiscount: -7.40999 LEI -
-10%
APC ACRD201
APC InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz, Statatoare, Negru, Water, Glycol, R410A, cUL Listed,C-tick,CE,UL Listed, 300 x 1070 x 1991 milimetri- Cod: ACRD201
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
73.69209 LEI cu TVA61.92613 LEI 12.208 12.458$ fără TVADiscount: -8.18801 LEI -
-10%
APC RACSC101E
APC InRow SC System, Statatoare, Negru, 0 - 95%, 0 - 40 °C, 900 x 1273 x 1991 milimetri, 42U- Cod: RACSC101E
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
70.06244 LEI cu TVA58.87600 LEI 11.607 11.845$ fără TVADiscount: -7.78472 LEI -
-10%
APC RACSC112E
APC InRow SC System, Statatoare, Negru, 900 x 1477 x 1991 milimetri, 42U- Cod: RACSC112E
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
84.49969 LEI cu TVA71.00814 LEI 13.999 14.285$ fără TVADiscount: -9.38885 LEI -
-10%
APC ACRD602
APC ACRD602, 600 milimetri, 1070 milimetri, 1991 milimetri, 39,1 kilograme, 850 milimetri, 1137 milimetri- Cod: ACRD602
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
Preturi la cererePreturile sunt vizibile pentru clientii autentificati -
-10%
APC ACRD602P
APC ACRD602P, 600 milimetri, 1070 milimetri, 1991 milimetri, 402 kilograme, 850 milimetri, 1137 milimetri- Cod: ACRD602P
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
Preturi la cererePreturile sunt vizibile pentru clientii autentificati -
-10%
APC ACRD101
APC InRow RD, 300mm, Air Cooled, 220-240V, 50Hz, Statatoare, Negru, Air, R410A, cUL Listed,C-tick,CE,UL Listed, 200/208/230- Cod: ACRD101
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
59.18315 LEI cu TVA49.73374 LEI 9.805 10.005$ fără TVADiscount: -6.57591 LEI -
-10%
APC RACSC201E
APC InRow SC System, Statatoare, Negru, 1200 x 1273 x 1991 milimetri, 42U- Cod: RACSC201E
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
114.78269 LEI cu TVA96.45604 LEI 19.016 19.405$ fără TVADiscount: -12.75363 LEI -
-10%
APC ACCD75232-C
APC ACCD75232-C, 1110 milimetri, 2090 milimetri, 1344 milimetri, 135 kilograme, 1270 milimetri, 2286 milimetri- Cod: ACCD75232-C
- Producător: APC
- Categorie: Uniflair Direct Expansion InRow Cooling
- Stoc: La comanda
Preturi la cererePreturile sunt vizibile pentru clientii autentificati